Chat with us, powered by LiveChat

Torrey Pines Scientific EchoTherm IC22 Digital, 2-Position Electronic Chilling/Heating Dry Bath

condition: Brand NewPart #: TP-IC22Availability: Call for Availability
Starting at $2,460.00
Select Options andView Options
×

Model Options *

Your Configured Product

TP-IC22
$2,460.00
Availability: Call for Availability

The completely solid-state EchoTherm™ IC22 2-Position Electronic Chilling/Heating Dry Bath is versatile, reliable and easy to use. Each heating/chilling station has its own Peltier module, and the entire unit has only two moving parts: the fans.

The chilling/heating surfaces are each 2.875” (7.3 cm) x 4.375” (11.1 cm) aluminum plates that are very flat for optimal contact with the sample blocks. When unloaded, the plates will reach below 0 °C in under two minutes. They will heat to 37°C in under a minute. The chilling and heating rates will change with loads. For instance, temperatures to 4.0°C can be reached on sample blocks as large as 4” (10.2 cm) x 3” (7.6 cm) x 6” (15.2 cm) in about 30 minutes.

OPTIONAL MODEL:
XT Model: Chilling range expanded to -20°C without sample block. Recommended for holding samples steady at low temperatures without cycling.

  • Energy-efficient Peltier design
  • Digital control to 1°C from -10 to 100°C
  • 2 separate temperatures on separate plates
  • Sample blocks for 0.2, 0.5 and 1.5 ml centrifuge tubes, 96-well and 384-well assay plates, 2ml vials, various sizes of test tubes and more.
  • Control at room temperature
  • 2 countdown timers (up to 30 days each) with alarm
  • RS232 I/O port for control or data collection
  • 2 data loggers
  • Electronic calibration.
  • Compact size. Small footprint on the bench
  • UL, CSA and CE compliant
  • 12-month warranty
  • Maintaining 14°C for ligation reactions
  • Maintaining 17°C for storing oocytes
  • Storing samples at ice bucket temperatures
  • Incubate samples in 96-well assay plates, or in aluminum blocks holding 0.2 ml, 0.5 ml or 1.5 ml centrifuge tubes
  • Cooling blood samples prior to coagulation testing
  • Storing enzymes or DNA libraries at your work station
  • Transporting samples from the field at exactly the right temperature
  • Chilling or heating samples in the field
  • Enzyme reactions and deactivations
  • Freezing and storing most any small sample at your workstation
  • PCR sample preparation
  • Hybridizations
  • General molecular biology applications

Temperature:

  • Range on each plate: -10°C to 100°C (IC22) -20C to 100C (IC22XT) w/o sample block
  • Readability: 1°C
  • Accuracy: ±1°C
  • Stability: ±1°C
  • Sensor Platinum: RTD
  • Controller Type: PID
  • Uniformity: ±0.5°C

Timers:

  • Range: 00:01 seconds to 30 days
  • Readability: 1 second
  • Audible Alarm: Yes, alarm sounds for 1 minute. Timer counts up until turned off.
  • Auto-Off: Yes, user settable.

Data Logger:

  • Sample times: 1 sec, 1 min or 5 minutes per data point
  • Capability: 8110 data points

Electrical:

  • Heater/Chiller: 50 watts each station. 100 watts total.
  • Operating Voltages: 90–265 Volts AC input to bench-top power supply, which provides 12 Volts DC to the unit
  • Power Consumption: 100 watts
  • Power Switch: Yes

Dimensions Chilling/Heating Module:

  • Chilling/Heating Module
  • Width 6.5” (16.5 cm)
  • Depth 14” (35.56 cm)
  • Height 3.5” (8.9 cm)
  • Weight 13 lbs (5.85 kg)

 

Your product has been sucessfully added to the wishlist.
Name: Torrey Pines Scientific EchoTherm IC22 Digital, 2-Position Electronic Chilling/Heating Dry Bath
Quantity: 1
Cart Total: $2,460.00
Product has been added to your shopping cart.
Name: Torrey Pines Scientific EchoTherm IC22 Digital, 2-Position Electronic Chilling/Heating Dry Bath
Quantity: 1
Cart Total: $2,460.00
Processing...

Create an Account