- Measurement Range: 0 to 53% for hardwood; 0 to 35% for softwood; relative readings for wallboard and masonry
- Measurement Accuracy: ±4% for hardwood and softwood
- Inductive Sensor Depth: 1.5 x 1.5 in. (38 x 38mm)
- Maximum Sensing Depth: 3/4 in. (20mm)
- Alarm Levels: >18% for wood; >70% for drywall and masonry
- LCD Size: 2 in. (50mm) diagonal with three 0.5 in. (13mm) high digits
- Bar Graph Composition: 3 each green, yellow and red LEDs
- Auto Power Off Trigger:2 minutes of inactivity
- Operating Temperature: 32° to 104°F (0° to 40°C) @ 5 to 95% RH
- Storage Temperature: 14° to 122°F (-10° to 50°C)
- Power Source: 1 “9V” battery
- Dimensions: 6.7 x 2.9 x 1.2 in. (170 x 75 x 30mm)
- Weight: 5.4 oz. (152g) without batter
LED Bands:
For Wood
-green = 0 to 30%
-yellow = 31 to 70%
-red = >70%
For Drywall and Masonry
-green = 5 to 13%
-yellow = 15 to 17%
-red = >18%