Manufacturer:

Compliance West HT-10KVP DC Hipot Tester, 14000 VDC

condition: Brand NewPart #: CW-HT-10KVP-DCAvailability: Call for Availability
Price $4,230.00

Compliance West HT-10KVP DC Hipot Tester Hipot Tester, 0-14kVdc @ 5mA. Ships complete with cables, manual, and Calibration Certificate.

The dielectric withstand test is a test which is recognized by safety agencies worldwide as a valid criterion of safe assembly of end-use equipment. The HT-10000P is designed as a research instrument to determine the dielectric properties of component assemblies of end-use equipment. It applies a high-voltage potential between Output and Return test leads and monitors Leakage Current and watches for Dielectric Breakdown during the test. To aid in testing, the HT-10000P can be configured with or without voltage ramp time, with or without a test duration timer, and can be set to deliver high voltage after an arc has been detected to pinpoint an area of arcing.

  • HT-10000P DC output to 14000 Volts. Delivers 1 through 5 milliamps.
  • Logic Controlled, One-button testing. LED indicators. Buzzer upon failure, test terminates. Test termination defeatable by switch on rear panel. Provided with arc detection circuit to properly detect hipot failures.
  • Rear panel adjustments; leakage limit, ramp time, test time and voltage.
  • Ergonomic design for safety and ease of use.
  • High voltage output jack.
  • Automatic voltage ramp-down circuit eliminates residual voltage.
  • Designed for product development and laboratory use.
  • High efficiency design, low power consumption.
  • All test leads included.
  • Calibrated to NIST standards.
  • 1 year warranty
  • HTT-1 and HTT-1RHipot and Ground Continuity Function Checker Compatible
  • Includes: Test leads, manual, and calibration certificate.
  • Voltage Test Type: DC
  • Voltage Range: 0-14000 VDC
  • Current Range: 4 mA
  • Input Voltage Requirements: 108-132 V, 50 /60 Hz, 2A max
  • Fuse Requirements: 120 VAC
  • Arc Detect: Separate high Frequency circuit
  • Leakage Detect: Separate Low frequency circuit
  • Ground Continuity: N/A
  • Ground Continuity Current: N/A
  • Test Time Range: 1 – 60 seconds
  • Ramp time Range: 1 – 5 Seconds
  • Voltage Meter Accuracy: ± 2 %
  • Current Meter Accuracy: ±0.1 mA
  • Resistance measure Range: N/A
  • Resistance auto offset Range: N/A
  • Resistance Measure Accuracy: N/A
  • HV shutdown by Ground Fail: N/A
  • Duty cycle: 100%
  • Discharge Time (Resistive Load) Transformer Output: < 500 VAC
  • Pass/Fail Repeatability: ± 3 %
  • Output connector: High Voltage Jack
  • Display: 4 digits LED display
  • Test indicator: Led indicators
  • Failure Indicator: Led indicators and buzzer
  • Programmable: No
  • PLC Interface: No
  • TestLink: N/A
  • Testminder: No
  • Voltage Hold on failure : Available
  • Top Mounted handle: No
  • Test Defeat: Ramp Time, Test Time and Breakdown Fail
  • Autoreset on Pass: Optional
  • Operation Temperature: 15 – 40 °C
  • Relative Humidity Range: 0 – 90 % Non-condensing
  • Dimensions : 10″ wide x 5″ high x 12″ deep
  • Weight: 17.5 Lb
  • Calibration: One year calibration Certificate
  • Test Cords: Return lead, High Voltage Test Lead, Power cord
  • HTS/Schedule B: 9030.39.0100
  • ECCN: 3B992
  • What is in the box: Return lead, High Voltage Test Lead, Power cord
Your product has been sucessfully added to the wishlist.
Name: Compliance West HT-10KVP DC Hipot Tester, 14000 VDC
Quantity: 1
Cart Total: $4,230.00
Product has been added to your shopping cart.
Name: Compliance West HT-10KVP DC Hipot Tester, 14000 VDC
Quantity: 1
Cart Total: $4,230.00
Processing...

Create an Account

Already have an account? Login