The Series PM-RM 1/8 DIN True RMS Meters, with Jumper-Selectable AC Signal Input Ranges are designed for process automation applications. The PMRM Series is a versatile family of controls with a multitude of input and output selections. The PM’s are fully scalable for customizing to the exact application requirements allowing the display to read in desired engineering units, ideal when using current and voltage signal transformers. Current input models can be set to one of 4 input ranges from 2.0000 mA with 0.1 μA resolution to 5.000 A with 1 mA resolution. The voltage input models may be set to one of 6 input ranges from 200.00 V with 10 μV resolution to 600.0 V with 0.1 V resolution. Universal AC or DC power options enable flexibility with usage in various power situations. The PM-RM’s offer optional 8 A contact or 120 mA solid state relay outputs, plus an analog process signal output with 4 user-selectable current or voltage ranges. To provide a higher level of communication and integration into a system’s network, several communication protocols such as RS-232, RS-485 and even USB options are available. These process meters possess exceptionally quick read rates to 60 conversions per second, while integrating the signal over a full power cycle. This fast read rate feature is ideal for peak or valley capture, on/off setpoint alarm or control applications.
The PM-RM True RMS Meters are ideal for AC loads found in applications like electrical motors which will only operate properly if the AC line voltage and frequency are within the motor’s specified tolerances. If the thresholds specified by the motor manufacturer are exceeded, permanent damage to the motor as well as plant equipment could occur. Drops in line voltage or frequency may indicate an excessive load and the possibility of equipment malfunction. In these situations, the PM-RM meters are a simple means to monitor AC power lines and provide an alarm of non-compliance.
Model | PM-RM |
Input Signal Ranges (Jumper Selectable) | RMA: 2.0000 mA, 20.000 mA, 200.00 mA, 5.000 A |
RMV: 200.00 mV, 2.0000 V, 20.000 V, 200.00 V, 300.0 V, 600.0 V | |
Display Range | 0 to 99999 |
Scaling Function | 5 digits with decimal point adjustment |
Accuracy @ 77°F (25°C) | ±0.1% of FS ±2 Counts; 5 A Range ±10 mA; 300 V & 600 V = ±0.8 V |
AC Range (True RMS Volts/Amps) | 0.1% to 100% of Full Scale, 10 Hz to 10 kHz, crest factor 3.0 |
Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V ac or 24 V dc; SSR: 120 mA @ 140 V ac or 180 V dc |
Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
Communication: (Optional) | RS-232, RS-485, USB |
Power Requirement | 85-264 V ac / 95-300 V dc; Optional 10-48 V dc / 12-34 V ac |
Ambient Temperature | 32-131°F (0-55°C) |
Dimensions | 1.89 x 3.78 x 4 in. (48 x 96 x 102 mm) 1/8 DIN. Panel Cutout: 1.77 x 3.62 in. (45 x 92 mm); Max. Panel Thickness: 0.18” (4.5 mm) |
Product Weight | 7.4 oz (210 g) |
Package Weight | 15.9 oz (450 g) |
Approvals | CE & RoHS |
Warranty | 1-Year |
AC Current
AC Current Range | AC Current to Overrange Flash | Resolution | Input Resistance |
2.0000 mA | 2.6400 mA | 0.1 μA | 100 Ω |
20.000 mA | 26.400 mA | 1.0 μA | 10 Ω |
200.00 mA | 264.00 mA | 10 μA | 1 Ω |
5.000 A | 5.4 A | 1 mA | 0.01 Ω |
AC Voltage
AC Voltage FS Range | AC Current to Overrange Flash | Resolution | Input Resistance |
200.00 mV | 264.00 mV | 10 μV | 22 MΩ |
2.000 V | 2.640 V | 100 μV | 1 MΩ |
20.000 V | 26.400 V | 1 mV | 1 MΩ |
200.00 V | 264.00 V | 10 mV | 1 MΩ |
600.0 V | 650 V | 0.1 V | 1 MΩ |