The 3198 can measure all waveforms of power, harmonic, and error events simultaneously. When a problem occurs with the equipment or system on your site, the 3198 will help you detect the cause of the problem early and solve it quickly. You can depend on the 3198 to monitor all aspects of your power supplies.
The 3198 can simultaneously record 8,000 or more parameters, such as voltage, current, power, power factor, frequency, integral power, harmonic, and flicker, at the specified recording interval. The 3198 never fails to capture the peak because it performs calculations continuously and records the maximum, minimum, and average values within the recording interval.
All Optional 3198 Power Quality Kits Include:
-3198 Power Quality Analyzer
-L1000 Voltage Cable Set
-Hard Carrying Case
-AC Adapter
-Rechargeable Battery Pack
-9624-50 PQA HiView Pro Software
-Z4001 2GB SD Card
Note: Voltage can be measured with the main unit alone. An optional current sensor is necessary to measure current or power parameters. Use Model 9624-50 PQA-HiVIEW PRO (version 2.00 or later) with a PC to analyze the data collected to the SD card.
Note: Voltage can be measured with the main unit alone. An optional current sensor is necessary to measure current or power parameters. Use Model 9624-50 PQA-HiVIEW PRO (version 2.00 or later) with a PC to analyze the data collected to the SD card.
Measurement Line Type | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel (must be synchronized to reference channel during AC/DC measurement) |
Voltage Ranges | Voltage measurement: 600.00 V rms Transient measurement 6.0000 kV peak |
Current Ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use) |
Basic Accuracy | Voltage: ±0.1% of nominal voltage Current: ±0.2% rdg. ±0.1% f.s. + current sensor accuracy Active power: ±0.2% rdg. ±0.1% f.s. + current sensor accuracy |
Measurement Items | 1. Transient over voltage : 2MHz sampling.
2. Frequency cycle : Calculated as one cycle, 40 to 70Hz 3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle. 4. Voltage swell, Voltage dips, Voltage interruption 5. Inrush current 6. Voltage waveform comparison 7. Instantaneous flicker value: As per IEC61000-4-15 8. Frequency: Calculated as 10 or 12 cycles, 40 to 70Hz 9. 10-sec frequency: Calculated as the whole-cycle time during the specified 10s period, 40 to 70Hz 10. Voltage waveform peak, Current waveform peak 11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor (negative-phase, zero-phase) 12. High-order harmonic component (voltage/ current): 2kHz to 80kHz 13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50th orders 14. Harmonic voltage-current phase angle: 1th to 50th orders 15. Total harmonic distortion factor (voltage/ current) 16. Inter harmonic (voltage/ current): 0.5Hz to 49.5Hz 17. K Factor (multiplication factor) 18. IEC Flicker, Δ V10 Flicker |
Record | 55 weeks (with repeated recording set to [1 Week], 55 iterations) 35 days (with repeated recording set to [OFF]) |
Interface | SD/SDHC card, RS-232C, LAN (HTTP server funtion), USB2.0 |
Display | 6.5-inch TFT color LCD (640×480 dots) |
Power Supply | AC ADAPTER Z1002 (12V DC, Rated power supply 100V AC to 240 V AC, 50/60Hz) BATTERY PACK Z1003 (Ni-MH 7.2V DC 4500mAh) |
Dimensions, mass | 300mm(11.81in)W × 211mm(8.31in)H × 68mm(2.68in)D (excluding protrusions), 2.6kg(91.7oz) (including battery pack) |
Supplied Accessories | Instruction manual×1, Measurement guide×1, VOLTAGE CORD L1000×1 set, Spiral Tube×20, Input Cable Labels×1, AC ADAPTER Z1002×1, Strap×1, USB cable (1m 3.28ft length)×1, BATTERY PACK Z1003×1, SD MEMORY CARD 2GB Z4001×1 |