New LCR METER Models IM3523, IM3533, and IM3533-01 are extremely cost-effective testers that provide higher performance and better functionality than previous HIOKI models, such as a wide measurement frequency range from 1 mHz (40 Hz for the IM3523) to 200 kHz, high-speed measurement of up to 2 ms, and highly reliable measurement using the contact-check function. Select the best model according to your application - from production lines to research and development.
Note: This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. All probes are constructed with a 1.5D-2V coaxial cable. For an RS-232C connection: A crossover cable for interconnection can be used. You can use the RS-232C CABLE 9637 without hardware flow control.
IM3533 | IM3533-01 | |
Measurement Modes | LCR, Transformer testing (N, M, ΔL), Continuous testing (LCR mode) | LCR, Transformer testing (N, M, ΔL), Analyzer (sweep testing), Continuous Testing (LCR/ Analyzer mode) |
Measurement Parameters | Z, Y, θ, Rs (ESR), Rp, DCR (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q, N, M, ΔL, T | |
Measurement Range | 100mΩ to 100MΩ, 10 ranges (All parameters defined in terms of Z ) | |
Displayable Range | Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp : ± (0.000000 [unit] to 9.999999G [unit]) Real value display for Z and Y only θ: ± (0.000° to 999.999°), D: ± (0.000000 to 9.999999) Q: ± (0.00 to 99999.99), Δ%: ± (0.0000% to 999.9999%) |
|
Basic Accuracy | Z : ±0.05%rdg. θ: ±0.03° | |
Measurement Frequency | 1mHz to 200kHz (1mHz to 10Hz steps) | |
Measurement Signal Level | [Normal mode] V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms steps CC mode: 10 μA to 50 mArms, 10 μArms steps [Low impedance high accuracy mode] V mode, CV mode: 5 mV to 2.5 Vrms, 1 mVrms step CC mode: 10 μA to 100 mArms, 10 μArms steps |
|
Output Impedance | Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω | |
Display | 5.7-inch touch-screen color TFT, display can be set to ON/OFF | |
Measurement Time | 2 ms (1 kHz, FAST, display OFF, representative value) | |
Functions | DC bias measurement, DC resistance temperature compensation (converted reference temperature display), Comparator, BIN measurement (classify function), Panel loading/saving, Memory function |
|
Interface | EXT I/O (Handler), USB communication (high-speed), USB memory Optional: Choose 1 from RS-232C, GP-IB, or LAN |
|
Power Supply | 100 to 240 V AC, 50/60 Hz, 50 VA max | |
Dimensions, mass | 330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) D, 3.1 kg (109.3 oz) | |
Supplied Accessories | Power cord ×1, Instruction Manual ×1, CD-R (Includes PC commands and sample software) ×1 |