The IM3536 raises the industry standard for general-purpose LCR meters by offering a wide DC and 4Hz to 8MHz testing frequency while delivering 0.05% accuracy, ideal for evaluating the characteristics of next generation electronic components, including power supply inductors thanks to the instrument’s maximum measurement frequency of 8MHz.

  • DC, 4Hz to 8MHz measurement frequency
  • High-speed measurement of 1ms (fastest time)
  • High-precision measurement of ±0.05% rdg. (representative value)
  • Guaranteed accuracy range from 1 mΩ, low-impedance measurement with unmatched repeatability
  • DC bias function: Measure under conditions simulating actual use or in accordance with industry standards
  • Exceptional specifications and cost-performance for a wide range of applications, from R&D to production lines
Measurement Modes LCR mode, Continuous measurement mode
Measurement Parameters Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), σ, ε
Measurement Range 100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
Display Range Z: 0.00 m to 9.99999 GΩ, Rs, Rp, Rdc, X: ±(0.00 m to 9.99999 GΩ)

G, B: ±(0.000 n to 9.99999 GS), Ls, Lp: ±(0.00000 μ to 9.99999 GH),

Cs, Cp: ±(0.0000 p to 9.99999 GF), Y: 0.000 n to 9.99999 GS,

θ : ±(0.000° to 999.999°), Q: ±(0.00 to 9999.99),

D : ±(0.00000 to 9.99999), Δ % : ±(0.000 % to 999.999%)

Basic Accuracy Z ±0.05% rdg. θ: ±0.03° (represestative value, Measurable range: 1 mΩ to 200 MΩ)
Measurement Frequency 4 Hz to 8 MHz (10 mHz to 100 Hz steps)
Measurement Signal Level [Normal mode: V mode/CV mode]

4 Hz to 1.0000 MHz: 10 mV to 5 V (maximum 50 mA)

1.0001 MHz to 8 MHz: 10 mV to 1 V (maximum 10mA)

[Low impedance high accuracy mode: V mode/CV mode]

4 Hz to 1.0000 MHz: 10 mV to 1 V (maximum 100 mA)

[Normal mode: CC mode]

4 Hz to 1.0000 MHz: 10 μA to 50 mA (maximum 5 V)

1.0001 MHz to 8 MHz: 10 μA to 10 mA (maximum 1 V)

[Low impedance high accuracy mode: CC mode]

4 Hz to 1.0000 MHz: 10 μA to 100 mA (maximum 1 V)

[DC resistance measurement]

Measurement signal level: Fixed at 1 V

DC Bias Measurement Generating range: DC voltage 0 V to 2.50 V (10mV resolution)

In low Z high accuracy mode: 0 V to 1 V (10 mV resolution)

Output Impedance Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
Display 5.7-inch color TFT with touch panel
Functions Comparator, BIN measurement (10 categories for 2 measurement parameters), Trigger function, Open/short compensation, Contact check, Panel loading/saving, Memory function
Interfaces EXT. I/O( HANDLER) ,USB, USB flash drive, LAN, GP-IB, RS-232C, BCD
Power Supply 100 to 240 V AC, 50/60 Hz, 50 VA max.
Dimensions and Mass 330 mm (12.99 in) W × 119 mm (4.69 in) H × 230 mm (9.06 in) D, 4.2 kg (148.1 oz)
Accessories Power cord ×1, Instruction manual ×1, LCR application disc (Communications user manual) ×1