DISCONTINUED ITEM
The 3143 is particularly useful for measuring the earth resistance of single rod electrodes found among aerial transmission line equipment and various types of safety box circuits, and incorporates a measurement principle that is different from that of the Earth HiTESTER 3151.
The 3143 is particularly useful for measuring the earth resistance of single rod electrodes found among aerial transmission line equipment and various types of safety box circuits, and incorporates a measurement principle that is different from that of the Hioki 3151 Earth HiTESTER.
Ground Resistance
20.0 to 49.9 ohm (±10 % rdg.), 50.0 to 500.0 ohm (±5 % rdg.)
Principle of Operation
Voltage comparison method (Measurement of voltage at loop impedance serial resonance)
Open circuit voltage: 0.9 V ACpeak typ. Testing current: 3.6 mA AC max. with terminals shorted, Testing frequency: 100 kHz to 1.5 MHz
Features
Energy saving mode, Resonance indicator, Battery check
Power Consumption
LR6(AA) alkaline batteries × 4, Continuous use: 8 hours
Dimensions, mass
155 (6.10in) W × 98 (3.86in) H × 49 (1.93in) D mm, 380g (13.4oz)
Supplied Accessories
MEASUREMENT CABLE 9265 (black 1 m (3.28 ft), red 20 m (65.62 ft), one each; CABLE WINDER × 1), LR6(AA) alkaline batteries × 4, CARRYING CASE 9338 × 1